Zhang Xiaogang
Associate Professor
Supervisor of Master's Candidates
- Master Tutor
- Education Level:PhD graduate
- Professional Title:Associate Professor
- Alma Mater:University of New South Wales
- Supervisor of Master's Candidates
- School/Department:School of Mechanical Engineering
- Discipline:Mechanical Design and Theory
- ZipCode:
- PostalAddress:
- Telephone:
- Email:
- Research
Biomechanics of Artificial Joint
The biomechanical environment after artificial joint replacement is an important standard to guide the design of the prosthesis, surgical installation, and revision of the prosthesis. Finite element analysis combined with musculoskeletal multi-body dynamics simulation is an effective method for biomechanical research. By establishing a multi-body dynamic model of bone and muscle including bones, muscles, ligaments and cartilage tissues, the biomechanical environment after the replacement of the main joints of the human body is studied, and the motion mode of the prosthesis and the precise boundary conditions for finite element research are obtained. Using the above analysis methods, the team has achieved excellent results in the research of hip and knee joint replacement and revision, temporomandibular joint and cervical joint replacement, and porous material properties.
Biotribology of Artificial Joint
For a long time, wear has been the bottleneck of the service performance and life of artificial joint prostheses. Aseptic loosening caused by wear debris is an important reason for the failure of artificial joints. In addition, the design trend of artificial joints has evolved from anatomical shapes to musculoskeletal mechanical functions. However, the requirements for joint kinematics and wear are contradictory. The collaborative optimization of musculoskeletal mechanical functions and tribological performance is still a world problem. The team used the above-mentioned bone-muscular multi-body dynamics analysis method, combined with tribological optimization design, focused on the key mechanism and core mechanism of the evolution of the artificial joint's in-vivo service behavior, and explored the regulation mechanism of the near-natural motion function and the life of the prosthesis.
The control mechanism of fixation interface loading and regeneration
The instability of the biological fixation interface is also an important factor that affects the life of the artificial joint and the patient's postoperative satisfaction. A large number of scientific research and clinical practice results have shown that the elastic modulus of metal materials is much higher than that of human bone tissue, resulting in serious mechanical mismatch and stress shielding, resulting in loosening of the metal prosthesis and bone tissue, making it difficult to meet the expected implantation effect. Stress shielding has become a key issue plaguing the development of orthopedic implants. Porous metal material is an effective method to solve this problem. The team intends to study the coupling effect of prosthetic material mechanics and biological tissue mechanics in the in vivo service environment, reveal the mapping relationship between the performance/repair function of the multi-level porous metal, and study the mechanics of the fixed interface in the body mechanics environment The control principle of the bearing and tissue regeneration function finally realizes the optimized design of the fixed surface bearing and regeneration.
Optimized design of personalized artificial joints
In recent years, researchers have found that the failure of the sliding surface and the fixed surface of the artificial joint is not an isolated event. Poor design of the sliding surface will affect the contact mechanics of the fixed surface and cause the fixed surface to loosen. In addition, the stability of the fixed surface will also affect the running effect of the sliding surface. Therefore, after artificial joint replacement, as long as one of the sliding surface and the fixed surface has a design and use defect, it is easy to cause the failure process to accelerate under the long-term mutual influence, and eventually cause the replacement to fail. It can be seen that independent sliding surface or fixed surface design improvement can no longer meet the current requirements, and the design trend of artificial joints should develop from the stage of independently solving the sliding surface wear problem and the fixed surface stability problem to the research of the sliding surface and the fixed surface coupling design. New stage.
- Xiaogang Zhang, Yali Zhang*, Zhongmin Jin. A semi-analytical approach to the elastic loading behaviour of rough surfaces. Friction, 2019.
- Wen Cui, Yanyan Bian, Hongkai Zeng, Xiaogang Zhang, Yali Zhang*, Xisheng Weng, Shixuan Xin, Zhongmin Jin. Structural and tribological characteristics of ultra-low-wear polyethylene as artificial joint materials. Journal of the Mechanical Behavior of Biomedical Materials, 2020 104: 103629.
- Jian Pu, Dongsheng Wu, Yali Zhang*, Xiaogang Zhang and Zhongmin Jin*. An Experimental Study on the Fretting Corrosion Behaviours of Three Material Pairs at Modular Interfaces for Hip Joint Implants. Lubricants. 2021, 9(2): 12.
- Xiaogang Zhang, Yali Zhang*, Zhongmin Jin. A semi-analytical approach to the elastic loading behaviour of rough surfaces. Friction, 2019.
- Wen Cui, Yanyan Bian, Hongkai Zeng, Xiaogang Zhang, Yali Zhang*, Xisheng Weng, Shixuan Xin, Zhongmin Jin. Structural and tribological characteristics of ultra-low-wear polyethylene as artificial joint materials. Journal of the Mechanical Behavior of Biomedical Materials, 2020 104: 103629.
- No content
- No content
- ***材料磨损性能比较试验
- 模拟体内力学环境下一种新型解剖型人工踝关节假体生物力学及磨损机理的研究
- The research on the biomechanics and Wearing Mechanism of a Newly Designed Anatomical Ankle Prosthesis after Total Ankle Arthroplasty
- Cooperative regulation mechanism of the in vivo bearing and regeneration of the fixation interface of biological artificial knee joints
- In-vivo behavior and control mechanism of high-function, long-life artificial joint interfaces